SRC-INITIAL: Set initial values for parameters of a source location model. Set the initial parameters of the source location model. The defaults if no initial parameters are set with src-initial or randomly generated (see src-gen.doc) is for the initial intensities, start times and stop times (if relevant) for all sources to be zero. The source locations are set to the middle of the allowed range. The number of sources, the noise degrees of free, the noise width parameter, and the wind speed (for the test flow model) are initially set to their minimum values. Usage: src-initial log-file { flow-parameter } / [ noise-width [ noise-df ] ] { / Q x y z [ start [ stop ] ] } Appends a record to the log file with index 0 that contains values for the flow parameters as given (or defaulting), the noise width and noise degrees of freedom as given (or defaulting), and zero or more intensities, coordinates, and start and stop times for sources (for any remaining sources, these parameters are zero). The number of sources is set to the number for which parameters were specified, or to the minimum, if that is larger. For the test flow model, the sole parameter is the wind speed; it defaults to its minimum value. Copyright (c) 2007 by Radford M. Neal